Removal of fluoride and pathogens from water using the combined electrocoagulation-inline-electrolytic disinfection process

dc.contributor.authorNjau, Oscar
dc.contributor.authorOtter, Philipp
dc.contributor.authorMachunda, Revocatus
dc.contributor.authorRugaika, Anita
dc.contributor.authorWydra, Kerstin
dc.contributor.authorNjau, Karoli
dc.date.accessioned2023-10-09T07:21:32Z
dc.date.available2023-10-09T07:21:32Z
dc.date.issued2023-07-01
dc.descriptionSDG 6: Clean Water and Sanitation SDG 3: Good Health and Well-being SDG 9: Industry, Innovation, and Infrastructureen_US
dc.description.abstractThe consecutive removal of fluoride (defluoridation) and pathogens (disinfection) in drinking water through combined electrocoagulation-inline-electrolytic disinfection (EC–ECl2) process with aluminum and dimension-stable mixed oxide electrodes was reported in this study. Laboratory trials were conducted on the effects of flow rate, initial pH, current density, and supporting electrolytes for defluoridation and disinfection processes. The results have shown that with a flow rate of 10 L/h, initial pH of 6, the current density of 9.4 mA/cm2 (EC cell) and 3.1 mA/cm2 (ECl2 cell), supporting electrolyte concentration of 165 mg/L, and electrolysis time of 50 min, a defluoridation rate of 88% (initial concentration of 12.3 mg/L) and complete disinfection (initial fecal coliforms of 19,700 colony-forming units per 100 mL (CFU/100 mL)) can be reached. The final concentration of fluoride and pathogens in treated water was 1.44 mg/L and 0 CFU/100 mL, which are within the acceptable limit of the World Health Organization and the Tanzania Bureau of Standards of 1.5 mg/L and 0 CFU/100 mL, respectively. The EC–ECl2 system is a promising approach for consecutive defluoridation and disinfection of water to save millions from fluorosis and waterborne diseases. However, optimization potential with regard to energetic efficiency and system complexity was identified.en_US
dc.identifier.urihttps://doi.org/10.2166/ws.2023.146
dc.identifier.urihttps://dspace.nm-aist.ac.tz/handle/20.500.12479/2132
dc.language.isoenen_US
dc.publisherIWA Publishingen_US
dc.subjectDefluoridationen_US
dc.subjectDisinfectionen_US
dc.subjectDrinking wateren_US
dc.subjectElectrocoagulationen_US
dc.subjectInline-electrolysisen_US
dc.subjectSupporting electrolyteen_US
dc.titleRemoval of fluoride and pathogens from water using the combined electrocoagulation-inline-electrolytic disinfection processen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
JA_MEWES_2023(3).pdf
Size:
775.58 KB
Format:
Adobe Portable Document Format
Description:
Full text

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2 KB
Format:
Item-specific license agreed upon to submission
Description: