    Abstract
    The purpose of this study was to investigate and demonstrate a cost-effective treatment technology for high turbid water, commonly used for domestic purposes in rural areas of Tanzania where conventional water treatment techniques are not available. A study was conducted on the water quality status of five permanent earth dams within Monduli district during the wet and dry seasons, by analyzing physicochemical and microbial characteristics. The water characteristics of the five earth dams tested were significantly correlated (p < 0.05) and most of the tested parameters including turbidity and faecal coliform (FC) were above the Tanzania Bureau of Standards (TBS) drinking water standards. In this study, a pilot-scale inclined plates settler integrated with constructed wetland (IPS-CW system was tested on Nadosoito dam water with turbidities ranging from 186 to 4011 NTU. The IPS-CW system was meant to remove organic matter, nutrients and pathogens, with major focus on turbidity and FC removal, at the test flow rates of 20, 15, 10 and 5 L/min. The system removed substantial amount of contaminants, thereby achieving maximum removal efficiency of 95.9% and 94.3% for turbidity and FC respectively. Although using this combination of technologies in improving drinking water quality is uncommon, nitrate and biochemical oxygen demand met the TBS and World health Organization drinking water standards of ≤ 50 mg/l and ≤ 6 mg/L respectively. Due to low production cost and simplicity in operation, the system can be implemented in rural communities with high turbidity water sources however, further disinfection is required to ensure zero FC.
    URI
    https://doi.org/10.58694/20.500.12479/1324
    Collections
    • Masters Theses and Dissertations

    Nelson Mandela-AIST copyright © 2021  DuraSpace
    Theme by 
    Atmire NV
     

     

    Browse

    All PublicationsCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Nelson Mandela-AIST copyright © 2021  DuraSpace
    Theme by 
    Atmire NV