Performance investigation of the slaughterhouse wastewater treatment facility: a case of Mwanza city slaughterhouse, Tanzania

dc.contributor.authorMichael, Semba
dc.date.accessioned2021-09-22T12:05:18Z
dc.date.available2021-09-22T12:05:18Z
dc.date.issued2021-01
dc.descriptionA Dissertation Submitted in Partial Fulfillment of the Requirements for the Degree of Master’s in Hydrology and Water Resources Engineering of the Nelson Mandela African Institution of Science and Technologyen_US
dc.description.abstractThe present study engaged onsite operations and laboratory analysis for Mwanza City Slaughterhouse (MCS) wastewater to improve the efficiency of wastewater treatment of a newly installed facility. The MCS wastewater treatment facility integrated with various unitsbiodigester (Batch Stirred Tank Bio-reactor), aeration unit, retention, clarifier, and a constructed wetland. During the initial runs, the MCS facility removed 87.5%, 92.2%, 43%, and 65.4% of effluent biochemical oxygen demand (BOD 5 ), chemical oxygen demand (COD), ammonium, and nitrate, respectively. Also, the parameters including pH, temperature, dissolved oxygen (DO) were used to control the system operations. After conducting effective plant operations for five months, the removal efficiencies of BOD 5 , COD, ammonium, and nitrate improved to 97.4%, 98.3%, 97.4%, and 97.6%. In the present study, the unit-by-unit performance values achieved as a result of alterations of the facility‟s running conditions presented. The MCS wastewater treatment facility found to be energy-positive, as it produced an average of 158.2 m 3 biogas per day. This amount of biogas, if converted to electricity, would be sufficient to run the facility operations. Generally, the MCS wastewater treatment facility attained the best performance as per design, achieving the effluent levels recommended by the Tanzania Standards (TZS). Also, the MCS treatment facility takes care of the environment and human health because of effluents released to the surrounding area are now within recommended standards.en_US
dc.identifier.urihttps://doi.org/10.58694/20.500.12479/1283
dc.language.isoenen_US
dc.publisherNM-AISTen_US
dc.rightsAn error occurred on the license name.*
dc.rights.uriAn error occurred getting the license - uri.*
dc.subjectResearch Subject Categories::NATURAL SCIENCESen_US
dc.titlePerformance investigation of the slaughterhouse wastewater treatment facility: a case of Mwanza city slaughterhouse, Tanzaniaen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MSc_HRWE_Semba_Michael_2021.pdf
Size:
1.53 MB
Format:
Adobe Portable Document Format
Description:
Full text

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2 KB
Format:
Item-specific license agreed upon to submission
Description: