Show simple item record

dc.contributor.authorMgaya, Jacqueline
dc.date.accessioned2022-08-29T11:06:16Z
dc.date.available2022-08-29T11:06:16Z
dc.date.issued2022-08
dc.identifier.urihttps://doi.org/10.58694/20.500.12479/1517
dc.descriptionA Dissertation Submitted in Partial Fulfilment of the Requirements for the Degree of Master of Science in Public Health Research of the Nelson Mandela African Institution of Science and Technologyen_US
dc.description.abstractThe study assessed the effects of different preservation methods and storage durations on the performance of mid-infrared spectroscopy for age-grading malaria transmitting mosquitoes. Laboratory-reared Anopheles arabiensis (N=3,681) were collected as 5 or 17-day olds and killed with ethanol then preserved using either silica desiccant at 5°C, freezing at -20°C, or absolute ethanol at room temperatures. For each preservation method, the mosquitoes were divided into three groups and stored for 1, 4 or 8 weeks, then scanned using the mid-infrared spectrometer. Supervised machine learning classifiers were trained with the infrared spectra, and used to predict the mosquito ages. The classification of mosquito ages (as 5 or 17-day old’s) was most accurate when the samples used to train the models and samples being tested were preserved the same way or stored for equal durations. However, when the test and training samples were handled differently, the classification accuracies declined significantly. Support vector machine classifiers (SVM) trained using spectra of silica-preserved mosquitoes achieved 95% accuracy when predicting the ages of other silica-preserved mosquitoes, but this declined to 72% and 66% when age-classifying mosquitoes preserved using ethanol and freezing. Similarly, models trained on one-week stored samples had declining accuracies of 97%, 83% and 72% when predicting ages of mosquitoes stored for 1, 4 or 8 weeks respectively. When using mid-infrared spectroscopy and supervised machine learning to age-grade mosquitoes, the highest accuracies are achieved when the training and test samples are preserved the same way and stored for the same durations. Protocols for infrared-based entomological studies should emphasize standardization of sample-handling procedures.en_US
dc.language.isoenen_US
dc.publisherNM-AISTen_US
dc.subjectResearch Subject Categories::NATURAL SCIENCESen_US
dc.titleEffects of sample preservation methods and storage duration on the performance of mid-infrared spectroscopy for predicting the age of malaria vectorsen_US
dc.typeThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record